Heat pumps provide both cooling in summer and heating in winter by reversing the flow of refrigerant using an electro-mechanical reversing valve. Because heat pumps operate year-round, components experience twice the operational hours of standard air conditioning systems, making proper maintenance and diagnostics critical.
Heat pumps provide both cooling in summer and heating in winter by reversing the flow of refrigerant using an electro-mechanical reversing valve. Because heat pumps operate year-round, components experience twice the operational hours of standard air conditioning systems, making proper maintenance and diagnostics critical.
Reversing valve solenoid de-energized or stuck in the heating position, or faulty O/B thermostat terminal wiring.
Malfunctioning defrost control board, bad defrost temperature sensor, or failed outdoor fan motor preventing defrost cycling.
Heat pump compressor locked out, low outdoor ambient temperature, or system running inefficient electric resistance strips.
Testing 24V energization to the reversing valve coil and measuring slide temperatures to detect internal refrigerant bypass.
Testing demand-defrost thermistors, sensor resistance, and defrost relay contact engagement.
Verifying crankcase heater operation to prevent refrigerant migration into compressor oil during cool off-cycles.
Switching system between heating and cooling to observe reversing valve shuttle movement and pressure differential shifts.
Measuring amperage across electric heat banks to verify proper staging without unnecessary power consumption.
Simulating defrost initiation to confirm outdoor fan shutdown and temporary supplemental heat engagement.
Verifying critical charge by weight or target subcooling to ensure balance in both cooling and heating cycles.
In cooling mode, a heat pump functions identically to a conventional air conditioner by absorbing heat from indoor air and rejecting it outdoors. The key difference is a 4-way reversing valve that allows the refrigerant flow to reverse in winter, extracting ambient heat from outdoor air and pumping it inside.
Unlike standard air conditioners that rest during autumn and winter, heat pumps run virtually all year long. A spring service prepares the system for intensive cooling, while a fall tune-up inspects the reversing valve, defrost controls, and auxiliary heat strips.
Call (888) 672-2966 for fast phone assistance.
Call (888) 672-2966